GAHM – Ground Active Hydrogen Maser

High Performance Frequency Stability Atomic Clock


The Ground Active Hydrogen Maser (GAHM) is Safran’s new proprietary frequency stability atomic clock. Designed for Ground Segment Space Applications (deep space tracking, geodesy, radioastronomy, …), GNSS Precise Time Stations, Autonomous time scale for defense and security, and, for National Metrology Institute to build the International atomic time (TAI) mandatory for UTC time.

The GAHM is backed by Safran’s successful 40-years track record of manufacturing high performance atomic clocks and fielding 200 units worldwide in High-level operational sites (extreme environmental sites, high level of maintainability).


Applications:


• Space applications – ground segment: VLBI,

• DeepSpace tracking, SLR/LLR, DORIS

• Precise Time Station/Facility: GNSS,

• Defense & Industrial autonomous Time Scales

• National Metrology Institute

R&D Test Facilities

특징

• Frequency Stability @ 1s: <1.5E-13 / @1d: <2.5E-15

• Phase noise @1Hz: <-130 dBc/Hz (5 MHz)

• Cavity technology for high gain performance

• Teflon & bulb coating technology over 20 years lifetime

• Low Sensitivity technology for higher stability performance

• Teflon & bulb coating technology over 20 years lifetime

• Low Sensitivity technology for higher stability performance <2E-15/C

• Warranty: 2 years

• Self-Diagnostics & maintenance free operations

• Lifetime: 20 years

규격

Frequency Stability

• t[s] 1

• standard 1,5E-13; typical 9E-14

• t[s] 10000

• standard 2,5E-15; typical 1,5E-15

1 pps
Signal terminaison [] Output 50; Input (sync) 50;
Standard Option Control – Range >±1E-11 Control – Resolution

The Ground Active Hydrogen Maser (GAHM) is Safran’s new proprietary frequency stability atomic clock. Designed for Ground Segment Space Applications (deep space tracking, geodesy, radioastronomy, …), GNSS Precise Time Stations, Autonomous time scale for defense and security, and, for National Metrology Institute to build the International atomic time (TAI) mandatory for UTC time.

The GAHM is backed by Safran’s successful 40-years track record of manufacturing high performance atomic clocks and fielding 200 units worldwide in High-level operational sites (extreme environmental sites, high level of maintainability).


Applications:


• Space applications – ground segment: VLBI,

• DeepSpace tracking, SLR/LLR, DORIS

• Precise Time Station/Facility: GNSS,

• Defense & Industrial autonomous Time Scales

• National Metrology Institute

• R&D Test Facilities

특징

• Frequency Stability @ 1s: <1.5E-13 / @1d: <2.5E-15

• Phase noise @1Hz: <-130 dBc/Hz (5 MHz)

• Cavity technology for high gain performance

• Teflon & bulb coating technology over 20 years lifetime

• Low Sensitivity technology for higher stability performance

• Teflon & bulb coating technology over 20 years lifetime

• Low Sensitivity technology for higher stability performance <2E-15/C

• Warranty: 2 years

• Self-Diagnostics & maintenance free operations

• Lifetime: 20 years

규격

Frequency Stability

• t[s] 1

• standard 1,5E-13; typical 9E-14

• t[s] 10000

• standard 2,5E-15; typical 1,5E-15

1 pps
Signal terminaison [] Output 50; Input (sync) 50;
Standard Option Control – Range >±1E-11 Control – Resolution